NEP Enclosed Generators

07th Jun 2015 Generator

Generator

Generators are large, noisy and potentially dangerous machines and so they demand particular care when it comes to their sitting and protection. NEP supplies generator acoustic canopies that can protect both the machinery and those who work with it from noise, vibration and the risk of fire. Protection from the weather can also be provided as well as security, safe access and ventilation. NEP’s enclosures are built to withstand the rough handling common on construction sites, and are of modular design with many interchangeable components for onsite repair if permitted
NEP’s enclosures incorporate the following features:

• High efficiency (Power / Emmissions / Sound) in a small footprint
• Versitile power connection options for easy set up
• Compact light weight design allows loading and unloading on vehicles
• Fully weatherproofed
• Control panel viewing window in lockable door
• Enclosed exhaust system
• Fuel fill and battery can only be reached via lockable access door.
• Optional forklift pockets
• Optional single point lift
• Optional bunded tank
• Excellent access for maintenance.
• Robust construction
• Highly corrosive resistant
• Lockable doors

Canopiesmodels and specifications

Acoustic Enclosures

B/N 85

P140/P150

P180/P200/P225/P250

P450/P500

P600/P650

Construction

Mild steel, Bolted

Acoustic insulation material

Barafoam

Exhaust position

External

External

Internal

Internal

Lifting facility

Central

Central

Canopy

Canopy

Control panel viewing window (perspex)

Standard

Cable access gland plate

Standard

Base fuel tank capacity (Litres)

330

460

970

970

Fuel tank type

Single skin

Finish

Gloss powder coat to RAL9010 (white)

P200/P225 & P250 BN85 canopy is now supplied with an external silencer and additional ventilation inlets for improved cooling

B/N 75 & B/N 85 Economy Models P8-P100

P8-P20

P25-P30

P40/P60

P65/#P80/P80/P100

Construction

Galvanised Mild steel, Bolted

Acoustic insulation material

Barafoam, Fully lined for B/N75, Partially lined for Economy version

Service access:

Combination of lockable hinged door(s) & bolted removeable panel(s)

Exhaust position:

Internal low level outlet

Lifting facility

Central Point & Forklift Pockets for B/N75. Central point lift not fitted to Economy version

Control panel viewing window (perspex)

Standard for B/N75. Not fitted to Economy version

Cable access gland plate

Standard

Radiator filler cap

Standard for B/N75. Not fitted to Economy version

Base fuel tank capacity (Litres)

66

90

130

200

Fuel tank type

Internally mounted &bunded within baseframe

Finish

Gloss powder coat to RAL9010 (white), Galvanised baseframe

Code P/P (Custom built type) available for all models

Code B/N 75 enclosure
Typical code B/N enclosure
Typical code P/P enclosure (with optional viewing window)

Construction/Acoustic insulation material Mild steel, Welded/Rockwool
Exhaust position/Lifting facility Roof mounted/From base
Control panel viewing window (perspex) Optional
Base fuel tank Single skin, sized for 8 hours @ 100% rated load
Finish Wet spray to a standard BS/RAL code